Performing upgrades
TheCCS4-USBswitchisfullyupgradeableviaashupgrade.Suchupgrades
require a Windows-based computer system to be linked via the OPTIONS port.
Items required to perform an upgrade
• Thesuppliedashupgradecable(VSC40).
• AWindows-basedcomputerwithanRS232serialport.
• ThelatestversionoftheKVMFirmwareUploaderandrmwarelesforthe
CCS4-USB switch - available from the Technical Support > Updates section
of the Adder Technology website (www.adder.com).
To use the KVM Firmware Uploader utility
1 - Obtain and run the KVM Firmware Uploader.
DownloadthelatestCCS4-USBswitchKVMFirmwareUploaderfromthe
Adder Technology website and install it on a Windows-based upgrade
computer that will be connected to the CCS4-USB switch. The files
are supplied as a compressed ZIP file. Decompress the ZIP file with an
appropriate tool such as WinZip (www.winzip.com) and copy all contained
files to the same folder on the upgrade computer.
2 - Power off the CCS4-USB switch
Remove the power supply plug from the rear panel of the switch.
3 - Connect the upgrade computer to the CCS4-USB switch
Connectthesuppliedashupgradecablebetweentheserialportofthe
Windows-based computer and the OPTIONS port on the rear panel of the
switch.
4 - Invoke upgrade mode
While powering on or when already powered: Press and hold the
COMPUTERandMODEbuttons(foruptotenseconds)untilthenumeric
indicator shows ‘ ’.
5 - Run the KVM Firmware Uploader utility
Fromthatfolder,selecttheKVMUploadericontoruntheupgradeutility.
TheKVMFirmwareUploaderdialogwillbedisplayed:
6 - Query the CCS4-USB switch
Click the Query Unit button to confirm that communication is possible with
the CCS4-USB switch and to establish its firmware details. If successful, the
‘Unit connected’ field should show the name of the CCS4-USB switch and
the current firmware will also be listed.
If the application cannot contact the CCS4-USB switch, re-check the
connection cable and click the Advanced... button to check that the correct
serial port is being used. Change the serial port within the Advanced...
section, if necessary.
continued
There is no need to adjust the computer’s serial port
settings as the application will do this automatically.
(Windows only)